Page 10 - ANGLGEAR CATALOG

SEO Version

800-713-6170
www.andantex.com
info@andantex.com
9
Selection Procedure
1. Determine the output speed and torque required for your application. The maximum recommended output
speed is 3000 rpm for 1:1 units, and 1500 rpm for 2:1 units. 2:1 units are NOT recommended for use as
speed increasers.
2. Select an application service factor from the chart to the right. Multiply your torque by the selected
service factor. If you are unsure of the factor to be used, please consult us.
3. Using the chart below, find your output speed on the left. If your speed is not shown, use the next highest
speed. Depending on the ratio you need (1:1 or 2:1), follow the chart across until you find a torque value
that is larger than your corrected torque value.
4. The Unit Size you need will be at the top of that column. There are 5 sizes available. At the bottom of the
column is a list of the various models available under the selected size. Select the model number, based
on the gear ratio and the number of shafts you need (2 or 3). When ordering, use the model number you
selected, along with the ratio desired.
5. Check the applied radial & thrust loads on the unit compared with the loads in the chart at the bottom.
If the applied loads are larger than the chart values, a larger unit must be selected.
6. Refer back to pages 4 & 5 for dimensional information on the model you selected.
OPERATING
UNIFORM MODERATE
CONDITIONS
LOAD
SHOCK
3
1
1.3
8
1.3
1.4
12
1.4
1.8
24
1.8
2.5
T (Nm) = 9,550 x kW / RPM
kW = T x RPM / 9,550
SERVICE FACTORS
SERVICE
(hours/day)
SELECTION & ORDERING INFORMATION, METRIC SERIES
SIZE 1
SIZE 2
SIZE 3
SIZE 4
SIZE 5
RATIO
1:1
2:1
1:1
2:1
1:1
2:1
1:1
2:1
1:1
2:1
SPEED
T
kW T kW T
kW T
kW T kW T kW T
kW T kW T
kW T
kW
50
4.70 0.02 1.25 0.01 16.60 0.09 5.02 0.03 50.5 0.26 27 0.14 89 0.47 39.1 0.20 132 0.69 72.2 0.38
100 4.20 0.04 1.09 0.01 14.50 0.15 4.65 0.05 44 0.46 26 0.27 79 0.83 37.4 0.39 118 1.24 67.7 0.71
200 3.70 0.08 0.96 0.02 12.60 0.26 4.42 0.09 38 0.80 24.5 0.51 69 1.45 36.1 0.76 102 2.14 63.3 1.33
300 3.40 0.11 0.91 0.03 11.60 0.36 4.20 0.13 34.7 1.09 23 0.72 62.9 1.98 34.9 1.10 93.2 2.93 61 1.92
400 3.20 0.13 0.86 0.04 10.90 0.46 3.97 0.17 32.5 1.36 22 0.92 58.7 2.46 33.2 1.39 86.9 3.64 56.6 2.37
500 3.07 0.16 0.84 0.04 10.45 0.55 3.86 0.20 31.1 1.63 21.5 1.13 55.9 2.93 32.3 1.69 82.7 4.33 55.1 2.88
750 2.79 0.22 0.77 0.06 9.70 0.76 3.64 0.29 28.7 2.25 20.3 1.59 50.2 3.94 30.2 2.37 74.1 5.82 50.4 3.96
1000 2.60 0.27 0.69 0.07 9.20 0.96 3.37 0.35 27.1 2.84 19 1.99 46.3 4.85 28.1 2.94 68.3 7.15 47.6 4.98
1250 2.48 0.32 0.65 0.09 8.83 1.16 3.20 0.42 26 3.40 18 2.36 43.5 5.69 26 3.40 64.1 8.39 44.1 5.77
1500 2.36 0.37 0.62 0.10 8.45 1.33 3.11 0.49 24.8 3.90 17.9 2.81 41.3 6.49 24.9 3.91 60.7 9.53 42.2 6.63
1750 2.25 0.41
8.00 1.47
23.7 4.34
39.3 7.20
57.4 10.5
2000 2.18 0.46
7.90 1.65
22.8 4.77
37.9 7.94
55.5 11.6
2500 2.06 0.54
7.80 2.04
21.3 5.58
35.3 9.24
51.6 13.5
3000 1.95 0.61
7.70 2.42
20.2 6.35
33.3 10.5
48.6 15.3
2-WAY
R3000M R3000-2M R3200M R3200-2M R3330M R3330-2M R3400M R3400-2M R3600M R3600-2M
3-WAY
R3100M R3100-2M R3300M R3300-2M R3350M R3350-2M R3500M R3500-2M R3700M R3700-2M
2-WAY
R3003M R3003-2M R3203M R3203-2M
3-WAY
R3103M R3103-2M R3303M R3303-2M
MODEL
DATA (kg)
R3000M R3100M R3200M R3300M R3330M R3350M R3400M R3500M R3600M R3700M
1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1 1:1 2:1
RADIAL LOAD 11.4 11.4 11.4 11.4 22.7 22.7 22.7 22.7 45.4 45.4 45.4 45.4 45.4 45.4 45.4 45.4 45.4 45.4 45.4 45.4
THRUST LOAD 22.7 22.7 22.7 22.7 45.4 45.4 45.4 45.4 90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7
WEIGHT
0.23 0.23 0.23 0.23 1.00 1.00 1.09 1.09 3.95 3.95 4.08 4.08 6.58 6.58 6.80 6.80 7.94 7.94 8.16 8.16
Selection Example
An application to connect a drive-shaft to a fan-shaft at a right-angle with a 1:1 ratio. Input & output connections with timing
belt pulleys at 1,000 rpm. Input power is 1 kW. Operating conditions are moderate shock, 12 hr/day.
1. Output speed is 1000 rpm. Operating torque = 9,550 x 1 kW / 1000 rpm = 9.55 Nm.
2. Service factor from chart (12 hours/day, moderate shock) - SF=1.3. Corrected torque = 9.55 x 1.3 = 12.42 Nm.
3. From ratings chart (output speed = 1000 rpm), unit torque = 27.1 Nm (> 12.42 Nm) - Size 3 1:1.
4. The model selected is: R3330M for two-way or R3350M for three-way.
5. The applied radial loads are calculated to be 33.6 kg on each shaft (< 45.4 kg), which is allowable.
6. On pages 7 & 8, the dimensions are checked to confirm available space for model selected.
OUTPUT SPEED (RPM)
* Unit ratings are: Output Torque in Nm and Output Power in kW.